Prospective comparison of PI-RADS version 2 and qualitative in-house categorization system in detection of prostate cancer.

JOURNAL OF MAGNETIC RESONANCE IMAGING(2018)

引用 25|浏览12
暂无评分
摘要
BackgroundPurposeProstate Imaging-Reporting and Data System v. 2 (PI-RADSv2) provides standardized nomenclature for interpretation of prostate multiparametric MRI (mpMRI). Inclusion of additional features for categorization may provide benefit to stratification of disease. To prospectively compare PI-RADSv2 to a qualitative in-house system for detecting prostate cancer on mpMRI. Study TypePopulationProspective. In all, 338 patients who underwent mpMRI May 2015-May 2016, with subsequent MRI/transrectal ultrasound fusion-guided biopsy. Field StrengthAssessment3T mpMRI (T2W, diffusion-weighted [DW], apparent diffusion coefficient [ADC] map, b-2000 DWI acquisition, and dynamic contrast-enhanced [DCE] MRI). One genitourinary radiologist prospectively read mpMRIs using both in-house and PI-RADSv2 5-category systems. Statistical TestResultsIn lesion-based analysis, overall and clinically significant (CS) tumor detection rates (TDR) were calculated for all PI-RADSv2 and in-house categories. The ability of each scoring system to detect cancer was assessed by area under receiver operator characteristic curve (AUC). Within each PI-RADSv2 category, lesions were further stratified by their in-house categories to determine if TDRs can be increased by combining features of both systems. In 338 patients (median prostate-specific antigen [PSA] 6.5 [0.6-113.6] ng/mL; age 64 [44-84] years), 733 lesions were identified (47% tumor-positive). Predictive abilities of both systems were comparable for all (AUC 76-78%) and CS cancers (AUCs 79%). The in-house system had higher overall and CS TDRs than PI-RADSv2 for categories 3 and 4 (P<0.01 for both), with the greatest difference between the scoring systems seen in lesions scored category 4 (CS TDRs: in-house 65%, PI-RADSv2 22.1%). For lesions categorized as PI-RADSv2=4, characterization of suspicious/indeterminate extraprostatic extension (EPE) and equivocal findings across all mpMRI sequences contributed to significantly different TDRs for both systems (TDR range 19-75%, P<0.05). Data ConclusionPI-RADSv2 behaves similarly to an existing validated system that relies on the number of sequences on which a lesion is seen. This prospective evaluation suggests that sequence positivity and suspicion of EPE can enhance PI-RADSv2 category 4 cancer detection. Level of Evidence: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1326-1335.
更多
查看译文
关键词
prostate,cancer,mpMRI,PI-RADSv2,detection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要