Iodine And Fat Quantification For Differentiation Of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography

Investigative Radiology(2018)

引用 62|浏览3
暂无评分
摘要
Objectives: The aim of this study was to investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine and fat quantification in differentiating adrenal gland adenomas from metastases.Materials and Methods: Sixty-two patients (38 men and 24 women; mean age, 69.1 years) underwent clinically indicated DECT of the abdomen on a third-generation dual-source scanner. Examinations were retrospectively included due to detected adrenal masses. For each adrenal lesion, unenhanced and contrast-enhanced attenuation values, as well as dual-energy iodine density and fat fraction, were recorded. Additional magnetic resonance imaging data, positron emission tomography/computed tomography scans, interval imaging follow-up, and histopathological analysis were used as the reference standard for all adrenal lesions. Mean values of unenhanced and contrast-enhanced attenuation, as well as material densities, were compared between adenomas, metastases, and normal adrenal glands. Furthermore, the diagnostic accuracy of unenhanced, contrast-enhanced, and material density analysis was assessed between adrenal adenomas and metastases.Results: Adrenal adenomas showed significant differences regarding iodine density and fat fraction values (1.3 0.4 mg/mL and 34.2% +/- 12.6%) in comparison with adrenal metastases (3.2 +/- 1.4 mg/mL and 10.7% +/- 7.8%) and normal adrenal glands (1.7 +/- 0.6 mg/mL and 18.7% +/- 12.0%) (all P <= 0.004). Analysis of unenhanced attenuation values revealed no significant differences between healthy adrenal parenchyma (19.1 +/- 15.6 HU) and adrenal metastases (26.9 +/- 16.2 HU) (P = 0.135). Iodine density and fat fraction analysis showed significantly higher diagnostic accuracy for the diagnosis of adenomas (sensitivity, 97% and 89%; specificity, 96% and 89%, respectively) compared with unenhanced and contrast-enhanced evaluation (sensitivity, 65% and 58%; specificity, 73% and 85%, respectively) (P <= 0.023). The combined diagnostic value of iodine density and fat fraction analysis revealed a sensitivity of 97% and a specificity of 100%.Conclusions: Third-generation dual-source DECT iodine and fat quantification allow for differentiation between adrenal adenomas and metastases with high diagnostic accuracy.
更多
查看译文
关键词
dual-energy CT, iodine quantification, adrenal gland, spectral imaging, diagnostic accuracy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要