Home Noninvasive Positive Pressure Ventilation With Built-In Software In Stable Hypercapnic Copd: A Short-Term Prospective, Multicenter, Randomized, Controlled Trial

INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE(2017)

引用 27|浏览14
暂无评分
摘要
Background: The benefits of noninvasive positive pressure ventilation (NPPV) in patients with hypercapnic COPD are controversial. It is presumed that methodology and appropriate use of NIV ventilator might be crucial for the outcomes. With the new built-in software, the performance of NIV can be monitored at home, which can guarantee the compliance and appropriate use. This study investigated effects of home use of NIV in hypercapnia in COPD patients using the NIV ventilator with built-in software for monitoring.Methods: The current multicenter prospective, randomized, controlled trial enrolled patients with stable GOLD stages III and IV hypercapnic COPD. Patients were randomly assigned via a computer-generated randomization sequence, with a block size of four patients, to continue optimized treatment (control group) or to receive additional NPPV (intervention group) for 3 months. The primary outcome was arterial carbon dioxide pressure (PaCO2). Data were derived from built-in software and analyzed every 4 weeks. Analysis was carried out with the intention to treat. This study is registered with ClinicalTrials.gov, number NCT02499718.Results: Patients were recruited from 20 respiratory units in China from October 1, 2015, and recruitment was terminated with a record of the vital statistics on May 31, 2016. A total of 115 patients were randomly assigned to the NPPV group (n=57) or the control group (n=58). Patients complied well with NPPV therapy (mean [+/- standard deviation] day use 5.6 +/- 1.4 h). The mean estimation of leaks was 37.99 +/- 13.71 L/min. The changes in PaCO2 (-10.41 +/- 0.97 vs -4.32 +/- 0.68 mmHg, P=0.03) and 6-min walk distance (6MWD) (38.2% vs 18.2%, P=0.02) were statistically significant in the NPPV group versus the control group. COPD assessment test (CAT) showed a positive trend (P=0.06) in favor of the NPPV group. Pulmonary function and dyspnea were not different between groups.Conclusion: Ventilators equipped with built-in software provided methodology for monitoring NIV use at home, which could facilitate the improvement of compliance and quality control of NIV use. It was shown that three months use of NIV at home could reduce the PaCO2 and improve exercise tolerance (6MWD) in chronic hypercapnic COPD patients.
更多
查看译文
关键词
COPD, noninvasive positive pressure ventilation, long-term oxygen therapy, chronic respiratory failure, built-in software
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要