Medial Patellofemoral Ligament Reconstruction: Impact of Knee Flexion Angle During Graft Fixation on Dynamic Patellofemoral Contact Pressure-A Biomechanical Study.

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association(2018)

引用 38|浏览14
暂无评分
摘要
PURPOSE:Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. METHODS:Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. RESULTS:No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). CONCLUSIONS:The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. CLINICAL RELEVANCE:Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要