A Multi-Wavelength, High-Contrast Contact Radiography System For The Study Of Low-Density Aerogel Foams

REVIEW OF SCIENTIFIC INSTRUMENTS(2016)

引用 3|浏览64
暂无评分
摘要
A multi-wavelength, high contrast contact radiography system has been developed to characterize density variations in ultra-low density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility and require precision characterization in order to reduce errors in measurements. The system was used to characterize density variations in carbon and silicon based aerogels to similar to 10.3% accuracy with similar to 30 mu m spatial resolution. The system description, performance, and measurement results collected using a 17.8 mg/cc carbon based JX-6 (C20H30) aerogel are discussed in this manuscript. Published by AIP Publishing.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要