Quantitative Conjugated Payload Measurement Using Enzymatic Release of Antibody-Drug Conjugate with Cleavable Linker.

BIOCONJUGATE CHEMISTRY(2017)

引用 22|浏览28
暂无评分
摘要
As antibody-drug conjugate (ADC) design is evolving with novel payload, linker, and conjugation chemistry, the need for sensitive and precise quantitative measurement of conjugated payload to support pharmacokinetics (PK) is in high demand. Compared to ADCs containing noncleavable linkers, a strategy specific to linkers which are liable to pH, chemical reduction, or enzymatic cleavage has gained popularity in recent years. One bioanalytical approach to take advantage of this type of linker design is the development of a PK assay measuring released conjugated payload. For the ADC utilizing a dipeptide ValCit linker studied in this report, the release of payload PF-06380101 was achieved with high efficiency using a purified cathepsin B enzyme. The subsequent liquid chromatography mass spectrometry (LC/MS) quantitation leads to the PK profile of the conjugated payload. For this particular linker using a maleimide-based conjugation chemistry, one potential route of payload loss would result in an albumin adduct of the linker-payload. While this adduct's formation has been previously reported, here, for the first time, we have shown that payload from a source other than ADC contributes only up to 4% of total conjugated payload while it accounts for approximately 35% of payload lost from the ADC at 48 h after dosing to rats.