Vessel Perforation and False Tracking Resulting From Umbilical Artery Catheterization: A Case Report and Literature Review.

PEDIATRIC AND DEVELOPMENTAL PATHOLOGY(2017)

引用 5|浏览1
暂无评分
摘要
We report an extremely low-birth-weight neonate who developed umbilical artery perforation and false tracking. There was no life-threatening event relating to the complication. Diagnosis was made at postmortem examination. Little information exists regarding the anatomic and vascular effects of umbilical artery catheterization placement in newborns. We report a new complication of umbilical artery catheterization. We raise the awareness regarding the potential life threat due to this rare but very serious complication.
更多
查看译文
关键词
umbilical artery catheterization,vessel perforation,false tracking,neonate