Impact of pixel size and shape on physics analyses

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2013)

引用 0|浏览3
暂无评分
摘要
The choice of the pixel shape and size in the r-ϕ and z-directions results in different position resolutions, that in turn, influence the impact parameter resolution. A study based on a Monte Carlo simulation is presented to quantify the effect of the impact parameter resolution on the search for new physics using the rare decay Bs0→μ+μ−. The presented study illustrates the performance of this search for different resolution scenarios. For an optimal result, it is found that the transversal and longitudinal impact parameter resolution must be balanced.
更多
查看译文
关键词
Pixel detector,Impact parameter resolution,Pixel resolution,Bs→μ+μ−