The TITAN in-trap decay spectroscopy facility at TRIUMF

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2015)

引用 21|浏览28
暂无评分
摘要
This paper presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF׳s Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta (2νββ) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.
更多
查看译文
关键词
In-trap decay spectroscopy,Beta-decay of highly charged ions,X-ray detection,Electron-beam ion trap,2νββ-decay nuclear matrix elements