Calibration and performance of the STAR Muon Telescope Detector using cosmic rays

Chenyang Yang,X J Huang,C M Du, B C Huang, Z Ahammed, Abhijeet Banerjee, P Bhattarari,S Biswas,Brian W Bowen,J M Butterworth,M Calderon De La Barca Sanchez, Helen Carson,Shital K Chattopadhyay, D Cebra,H F Chen,J P Cheng,M J M Codrington, G Eppley,C Flores,F J M Geurts,G W Hoffmann, A Jentsch,A Kesich,Chunlai Li,Y J Li,W J Llope,S Mioduszewski, Y Mohamed, T Nussbaum,A K Roy,Li Ruan, J Schambach,Y J Sun,Yang Wang,K Xin,Zongli Xu,S Yang, X L Zhu

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2014)

引用 28|浏览6
暂无评分
摘要
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100ps and ~1–2cm. These values are comparable to those obtained from cosmic-ray bench tests and test beams.
更多
查看译文
关键词
Muon telescope detector,Cosmic ray,Timing resolution,Spatial resolution