Does implantation of larger bioprosthetic pulmonary valves in young patients guarantee durability in adults? Durability analysis of stented bioprosthetic valves in the pulmonary position in patients with Tetralogy of Fallot †.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY(2016)

引用 19|浏览10
暂无评分
摘要
In a previous study, we identified factors affecting the durability of bioprosthetic valves in the pulmonary position following total repair of Tetralogy of Fallot (TOF). In this study, we aimed to identify factors affecting the durability of the bioprosthetic valve with regard to patient age and implanted valve size in order to guide valve choice in adolescent patients. We enrolled and analysed 108 cases of pulmonary valve replacement (PVR) with stented bioprosthetic valves in TOF patients between January 1998 and February 2014. Valvular dysfunction was defined as at least a moderate amount of pulmonary regurgitation or a peak pressure gradient of a parts per thousand yen40 mmHg on the most recent echocardiography. We analysed the effect of patient age and valve size on the durability of the bioprosthetic valve in the pulmonary position. There were 2 early deaths; no late deaths were observed. The follow-up duration was 92.8 +/- 44.5 months. The mean age at PVR was 19.3 +/- 9.1 years. The mean valve size was 24.7 +/- 1.8 mm. Whereas patients a parts per thousand yen20 years old showed no valvular dysfunction (i.e. 100% freedom from valvular dysfunction at 10 and 14 years), patients who were adolescents and children (< 20 years) showed worse durability, regardless of the z-score of valve size (68.2% at 10 years and 24.7% at 14 years). Although a larger valve with a z-score of a parts per thousand yen2 was implanted, patients < 20 years old did not exhibit good valvular durability. The results were particularly worse in patients < 10 years old, with 66.7% freedom from valvular dysfunction at 6 years and 33.3% at 8 years, compared with patients within the age range of 10 to < 20 years (75.1% at 10 years, and 20.5% at 14 years). The durability of bioprosthetic valves in the pulmonary position was acceptable in patients aged a parts per thousand yen20 years, regardless of the z-score of valve size. However, patients who were children and adolescents did not show optimal durability of the bioprosthetic valve, irrespective of the z-score of valve size.
更多
查看译文
关键词
Congenital heart disease,Tetralogy of Fallot,Pulmonary valve,Prosthetic valve
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要