Plasma density measurements in tungsten wire-array Z-pinches

PHYSICS OF PLASMAS(2012)

引用 11|浏览8
暂无评分
摘要
Measurements of the plasma density profile near the exploding wires in 1 MA tungsten (W) wire-array Z-pinches have been made using calibrated x-ray absorption. As many as 5 x-ray images per pulse were obtained between 65 and 160 ns after the start of the 100 ns rise time current pulse. Measured W ion densities range from above 10(19)/cm(3) close to the wire to similar to 10(17)/cm(3) about 1 mm away from the wire in the plasma stream. After accurate geometrical registration of the individual wires in each successive image in a pulse using the Genetic Algorithm, the temporal evolution of the axial modulation wavelength distribution of the ablation rate from the wires in each array and the global mass-ablation rate as a function of time are presented. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4736986]