Simultaneous Measurement Of Ignition Energy And Current Signature For Brush Discharges

PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ELECTROSTATICS: ELECTROSTATICS 2011(2011)

引用 3|浏览3
暂无评分
摘要
Accurate prediction of the probability of ignition arising from charged insulators is a crucial element of risk assessment in process industry. Incendiary brush discharges can occur when a large or grounded conductor approaches a charged insulator in the presence of a flammable atmosphere. This paper describes ignition tests based on an IEC standard method and simultaneously recorded temporal distribution of current released in the discharges, using a discharge probe integrated with the ignition probe. Ignition and non-ignition results are compared with peak discharge current and charge transferred in the discharge. No clear ignition threshold was found for either of these parameters. No major differences were found between igniting and non-igniting waveforms.