Adapting a geared domestic refrigerative dehumidifier for low-temperature operation

International Journal of Refrigeration(2014)

引用 6|浏览1
暂无评分
摘要
It has been established that geared domestic refrigerative dehumidifiers behave poorly when operated in low-temperature household environments where frosting of the evaporator occurs. The hot-side temperature drop introduced by the air-side evaporator economiser is a primary factor in the poor performance of the system if the economiser is too efficient. In this paper, methods for pushing the geared dehumidifier frosting limit to lower ambient temperatures are explored numerically and implemented experimentally with a test system. The methods tested here include a modified refrigerant evaporator, control of the economiser's thermal effectiveness and an integrated approach which includes both methods in conjunction with variable air flow. Results presented in this paper demonstrate operation of a geared domestic dehumidifier with improved dehumidification capacity over the conventional system by around 10% at a moist air condition of 15.4 °C, 70% relative humidity, without evaporator frosting.
更多
查看译文
关键词
Geared dehumidifier,Frosting,Air conditioning,Dehumidification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要