Transducer Excitation With Switched-Mode Encoded Signals For Harmonic And Amplitude Control Verified Using The Leach Model

2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS)(2013)

引用 1|浏览5
暂无评分
摘要
An excitation method to reduce harmonic content in the third harmonic was verified utilizing SPICE modeling. The SPICE model incorporated a MOSFET model and the Leach model to form a multi-level switch-mode pulser circuit. The pulser circuit was driven with a Harmonic Reduction PWM excitation sequence and a stepped excitation sequence with a fundamental frequency of 2 Mhz. An FFT of the excitation sequences was compared to verify the performance of the MOSFETs with the excitation sequences. It was found that at the third harmonic, the harmonic content was reduced by 22.2 dB.
更多
查看译文
关键词
transducers,ultrasonic transducers,acoustics,mosfet model,harmonic analysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要