Endovenous Laser Therapy For Occlusion Of Incompetent Saphenous Veins Using 1940nm

Ronald Sroka, Thomas Pongratz, Anna Esipova, Slobodan Dikic, Sahit Demhasaj, Florin Comsa,Claus-Georg Schmedt

MEDICAL LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS VII(2015)

引用 6|浏览4
暂无评分
摘要
Objective: Several studies indicate that ELT using wavelengths of high water absorption showed advantages compared to conventional ELT. Thulium-Lasers emit nearby the local absorption maximum of water at 1940nm. In this clinical study the effectiveness, safety and the feasibility of 1940nm-ELT is proven.Materials and Method: A single centric, prospective observational study was performed. 1940nm-laserenergy was applied using radial emitting fibres with continuous pullback (1mm/s). Treatment was performed under anesthesia (general, spinal, tumescent) thus simultaneous miniphlebectomy and ligation of perforators could be applied. Patient and technical details were systematically collected. Evaluation included: standardized questionnaire, clinical examination, color-duplex ultrasonography preoperatively, 3d, 4w, 6m postoperatively, statistic.Results: The 1940nm-ELT study include 55 patients (female/men=34/21, mean age 55y, range 23-90y) treating n=72 vessels. The mean maximum diameter of great saphenous veins (GSV, n=59) was 7.5mm (range 3.7-11.3mm) and of small saphenous veins (SSV, n=13) was 5.3mm (3.0-10.0mm). The mean applied longitudinal endovenous energy density (LEED) was 64.3J/cm (40.3-98.2J/cm) in GSVs and 51.0J/cm (37.6-72.7J/cm) in SSVs. Complete occlusion of the vein without sign of reflux was achieved in 100%. The mean length of non-occluded stump at the sapheno-femoral junction was 6.0mm (1.0-20.0mm). Postoperative reduction of the diameter of GSV was 1.6mm (21.3%) and 2.0mm (37.7%) in SSV. One (1.4%) endovenous heat induced thrombus (EHIT) was observed. Further adverse events were: paresthesia 10/72 (13.9%), ecchymosis 1/72 (1.4%), lymphocele 1/72 (1.4%), hyperpigmentation 1/72 (1.4%). The mean postoperative pain intensity was 1.3 and 1.8 single doses of analgesics were administered. Normal physical activity was reached after 3d (1-21d).Conclusion: 1940nm-ELT using radial light application effectively eliminates the reflux in insufficient saphenous veins by a significant diameter reduction. The risk profile correlates with other endothermal treatment options. Low postoperative pain and analgesic requirements with rapid convalescence indicate a high level of patient comfort.
更多
查看译文
关键词
Thulium-Fiberlaser 1940nm,varicose vein,ELT
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要