Calibration of pulse transit time through a cable for EAS experiments

CHINESE PHYSICS C(2014)

引用 1|浏览6
暂无评分
摘要
In ground-based extensive air shower experiments, the direction and energy are reconstructed by measuring the relative arrival time of secondary particles, and the energy they deposit. The measurement precision of the arrival time is crucial for determination of the angular resolution. For this purpose, we need to obtain a precise relative time offset for each detector and to apply the calibration process. The time offset is associated with the photomultiplier tube, cable, relevant electronic circuits, etc. In view of the transit time through long cables being heavily dependent on the ambient temperature, a real-time calibration method for the cable transit time is investigated in this paper. Even with a poor-resolution time-to-digital converter, this method can achieve high precision. This has been successfully demonstrated with the Front-End-Electronic board used in the Daya Bay neutrino experiment.
更多
查看译文
关键词
EAS experiment,time-walk effect,real-time calibration,transit time
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要