Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography

Journal of echocardiography(2013)

引用 1|浏览23
暂无评分
摘要
A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.
更多
查看译文
关键词
Prosthetic tricuspid valve,Three-dimensional transesophageal echocardiography,Three-dimensional transthoracic echocardiography,Prosthetic valve dysfunction