Atlas Monitored Drift Tube Long-Term Stability And Aging Study Performed For The First Time With The Gas-Recirculation System Planned For Lhc

2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5(2004)

引用 0|浏览1
暂无评分
摘要
The Monitored Drift Tubes (MDTs) of the Atlas muon spectrometer have to sustain count rates up to 1500 Hz/cm and must be able to survive an accumulated charge of up to 0.6 C/cm during 10 years of operation. This paper presents results of aging studies carried out at the CERN Gamma Irradiation Facility GIF for the first time with a final Atlas muon chamber and a prototype of the gas recirculation system planned at LHC. A loss in pulse height was observed for MDTs under gas recirculation after an accumulated charge equivalent to only I year of LHC operation; the effect was traced to a silicone contamination from bad components in the gas recirculation system. Tubes operated with the classical one-pass, flushing mode did not show any evidence of aging, thus (re)validating the materials and components used in the MDT construction.Questions of long-term stability when recycling the major part of the operating gas could also be addressed by the measurements performed; results on this will also be discussed.
更多
查看译文
关键词
ageing
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要