Development and underground test of radiopure ZnMoO4 scintillating bolometers for the LUMINEU 0 nu 2 beta project

E Armengaud,Q Arnaud,C Augier, A Benoit, L Berge,R S Boiko,T Bergmann,Joe B Blumer,A Broniatowski,V B Brudanin, P Camus,A Cazes, M Chapellier,F Charlieux,D M Chernyak,N Coron, P W Coulter,F A Danevich,T De Boissiere,Rodolphe Decourt,M De Jesus, L Devoyon, A A Drillien,L Dumoulin,K Eitel,Christian Enss, D Filosofov, A Fleischmann, N Foerster,N Fourches,J Gascon,L Gastaldo,G Gerbier,Andrea Giuliani, D J Gray,M Gros,L Hehn, S Henry, S Herve, G Heuermann,V Humbert, I M Ivanov,A Juillard, C Kefelian, M Kleifges,H Kluck,V V Kobychev, F Koskas,Vladimir Kozlov, H Kraus,V Kudryavtsev,H Le Sueur,M Loidl,P Magnier, E P Makarov,M Mancuso,P De Marcillac,S Marnieros, C Marrachekikuchi, A Menshikov, S G Nasonov,X F Navick,C Nones,E Olivieri,P Pari,Bipul C Paul, Y Penichot,G Pessina,M C Piro, O Plantevin,D V Poda, T Redon,Matthew R Robinson,Miguel R D Rodrigues,S Rozov,V Sanglard, B Schmidt,S Scorza,V N Shlegel, B Siebenborn, O Strazzer, D Tcherniakhovski, M Tenconi,L Torres,V I Tretyak,L Vagneron,Ya V Vasiliev,M Velazquez, O Viraphong,R J Walker, M Weber,E Yakushev,Xinmei Zhang, V N Zhdankov

JOURNAL OF INSTRUMENTATION(2015)

引用 35|浏览70
暂无评分
摘要
The LUMINEU (Luminescent Underground Molybdenum Investigation for NEUtrino mass and nature) project envisages a high-sensitivity search for neutrinoless double beta (0 nu 2 beta) decay of Mo-100 with the help of scintillating bolometers based on zinc molybdate (ZnMoO4) crystals. One of the crucial points for the successful performance of this experiment is the development of a protocol for producing high quality large mass ZnMoO4 crystal scintillators with extremely high internal radiopurity. Here we report a significant progress in the development of large volume ZnMoO4 crystalline boules (with mass up to 1 kg) from deeply purified materials. We present and discuss the results achieved with two ZnMoO4 samples (with mass of about 0.3 kg each): one is a precursor of the LUMINEU project, while the other one was produced in the framework of LUMINEU with an improved purification / crystallization procedure. The two crystals were measured deep underground as scintillating bolometers in the EDELWEISS dilution refrigerator at the Laboratoire Souterrain de Modane (France) protected by a rock overburden corresponding to 4800 m w.e. The results indicate that both tested crystals are highly radiopure. However, the advanced LUMINEU sample shows a clear improvement with respect to the precursor, exhibiting only a trace internal contamination related with Po-210 at the level of 1 mBq/kg, while the activity of Ra-226 and Th-228 is below 0.005 mBq/kg. This demonstrates that the LUMINEU purification and crystal-growth procedures are very efficient and leads to radiopurity levels which exceedingly satisfy not only the LUMINEU goals but also the requirements of a next-generation 0 nu 2 beta experiment.
更多
查看译文
关键词
Double-beta decay detectors,Cryogenic detectors,Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators),Hybrid detectors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要