Experimental study of electric breakdowns in liquid argon at centimeter scale

JOURNAL OF INSTRUMENTATION(2014)

引用 18|浏览10
暂无评分
摘要
In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1mm to 40mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).
更多
查看译文
关键词
Avalanche-induced secondary effects,Noble liquid detectors (scintillation, ionization, double-phase),Voltage distributions