Extrinsic compression of the left main coronary artery by a contained aortic annular rupture following trans-catheter aortic valve implantation
Cardiovascular Revascularization Medicine(2015)
摘要
We present a case of an 83-year-old female who suffered from annular rupture with contained hematoma immediately after trans-apical implantation of balloon-expandable Sapien valve. The patient developed acute cardiogenic shock which resulted from an extrinsic compression of the left main coronary artery. We report the successful management of this complication.
更多查看译文
关键词
TAVR,Annular rupture,PCI,Complication