Comparison of field-of-view (FOV) optimized and constrained undistorted single shot (FOCUS) with conventional DWI for the evaluation of prostate cancer.

Clinical Imaging(2015)

引用 25|浏览6
暂无评分
摘要
Qualitative and quantitative comparison of the application value of diffusion-weighted imaging (DWI) magnetic resonance imaging based on field-of-view (FOV) optimized and constrained undistorted single shot (FOCUS) with the standard single-shot echo-planar imaging (ss-EPI) in patients with prostate cancer.A total of 28 patients with 33 prostate cancers underwent ss-EPI and FOCUS DWI. Two independent readers assessed image studies.Image qualities of FOCUS were rated superior to ss-EPI (P<.001). The mean apparent diffusion coefficient value of 33 cancers was 974.030×10(-6)mm(2)/s and 941.727×10(-6)mm(2)/s, respectively, and the difference was statistically significant (t=2.579, P=.015).FOCUS as a high-resolution DWI technique has potential clinical utility.