Comparison of subdural and subgaleal recordings of cortical high-gamma activity in humans.

Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology(2015)

引用 17|浏览12
暂无评分
摘要
OBJECTIVE:The purpose of this study is to determine the relationship between cortical electrophysiological (CE) signals recorded from the surface of the brain (subdural electrocorticography, or ECoG) and signals recorded extracranially from the subgaleal (SG) space. METHODS:We simultaneously recorded several hours of continuous ECoG and SG signals from 3 human pediatric subjects, and compared power spectra of signals between a differential SG montage and several differential ECoG montages to determine the nature of the transfer function between them. RESULTS:We demonstrate the presence of CE signals in the SG montage in the high-gamma range (HG, 70-110 Hz), and the transfer function between 70 and 110 Hz is best characterized as a linear function of frequency. We also test an alternative transfer function, i.e. a single pole filter, to test the hypothesis of frequency dependent attenuation in that range, but find this model to be inferior to the linear model. CONCLUSIONS:Our findings indicate that SG electrodes are capable of recording HG signals without frequency distortion compared with ECoG electrodes. SIGNIFICANCE:HG signals could be recorded minimally invasively from outside the skull, which could be important for clinical care or brain-computer interface applications.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要