摘要
Background For yttrium-90 ( 90 Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ( 99m Tc) macroaggregated albumin (MAA) single photon emission computed tomography with integrated CT (SPECT/CT) of the lung as part of our routine dosimetric protocol for 90 Y radioembolization. Its rationales are the technical superiority of SPECT/CT over planar scintigraphy, ease and convenience of lung auto-segmentation CT densitovolumetry, and dosimetric advantage of patient-specific lung parenchyma masses. Methods This is a retrospective study of our pulmonary clinical outcomes and comparison of lung dosimetric accuracy and precision by 99m Tc MAA SPECT/CT versus conventional planar methodology. 90 Y resin microspheres (SIR-Spheres) were used for radioembolization. Diagnostic CT densitovolumetry was used as a reference for lung parenchyma mass. Pulmonary outcomes were based on follow-up diagnostic CT chest or X-ray. Results Thirty patients were analyzed. The mean lung parenchyma mass of our Southeast Asian cohort was 822 ± 103 g standard deviation (95% confidence interval 785 to 859 g). Patient-specific lung parenchyma mass estimation by CT densitovolumetry on 99m Tc MAA SPECT/CT is accurate (bias −21.7 g) and moderately precise (95% limits of agreement −194.6 to +151.2 g). Lung mean radiation absorbed doses calculated by 99m Tc MAA SPECT/CT and planar methodology are both accurate (bias <0.5 Gy), but 99m Tc MAA SPECT/CT offers better precision over planar methodology (95% limits of agreement −1.76 to +2.40 Gy versus −3.48 to +3.31 Gy, respectively). None developed radiomicrosphere pneumonitis when treated up to a lung mean radiation absorbed dose of 18 Gy at a median follow-up of 4.4 months. Conclusions Personalized predictive lung dosimetry by 99m Tc MAA SPECT/CT is clinically feasible, safe, and more precise than conventional planar methodology for 90 Y radioembolization radiation planning.
更多
查看译文
关键词
ct lung densitovolumetry,lung mass,partition model,selective internal radiation therapy,technetium-99m macroaggregated albumin spect/ct,yttrium-90 radioembolization,orthopedics,cardiology,oncology,nuclear medicine
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要