Can dual-energy CT improve the assessment of tumor margins in oral cancer?

Oral oncology(2013)

引用 41|浏览8
暂无评分
摘要
OBJECTIVES:The aim was to investigate the image quality of dual-energy computed-tomography (DECT) compared to single-energy images at 80 kV and 140 kV in oral tumors. MATERIALS AND METHODS:Forty patients underwent a contrast-enhanced DECT scan on a definition flash-CT. Four reconstructions (80 kV, 140 kV, mixed (M), and optimum-contrast (OC)) were assessed by four blinded readers for subjective image quality (10-point scale/10=best). For objective quality assessment, linear attenuation measurements (line density profiles (LDP)) were positioned at the tumor margin, and the difference between minimum and maximum was calculated. Signal-to-noise ratios (SNR) were measured in the tongue. RESULTS:The mean image quality for all readers was 5.1±0.3, 8.4±0.3, 8.1±0.2, and 8.3±0.2 for the 140 kV, 80 kV, M, and OC, respectively (P<001 between 140 kV and all others). The mean difference between the minimum and maximum within the LDP was 139.4±59.0, 65.7±29.5, 105.1±46.5, and 118.7±59.4 for the 80 kV, 140 kV, M, and OC, respectively (P<001). The SNR for the tongue was 3.8±2.1, 3.8±2.1, 4.2±2.4, and 4.1±2.3 for the 80 kV, 140 kV, M, and OC, respectively. DISCUSSION:DECT of oral tumors offers high image quality, with subjectively rated image quality and attenuation contrast at the tumor margin similar to that of 80 kV; DECT, however, provides a significantly higher SNR compared to 80 kV.