High-throughput quantitative analysis with cell growth kinetic curves for low copy number mutant cells

Analytical and bioanalytical chemistry(2012)

引用 4|浏览2
暂无评分
摘要
The mutation rate in cells induced by environmental genotoxic hazards is very low and difficult to detect using traditional cell counting assays. The established genetic toxicity tests currently recognized by regulatory authorities, such as conventional Ames and hypoxanthine guanine phosphoribosyl-transferase (HPRT) assays, are not well suited for higher-throughput screening as they require large amounts of test compounds and are very time consuming. In this study, we developed a novel cell-based assay for quantitative analysis of low numbers of cell copies with HPRT mutation induced by an environmental mutagen. The HPRT gene mutant cells induced by the mutagen were selected by 6-thioguanine (6-TG) and the cell’s kinetic growth curve monitored by a real-time cell electronic sensor (RT-CES) system. When a threshold is set at a certain cell index (CI) level, samples with different initial mutant cell copies take different amounts of time in order for their growth (or CI accumulation) to cross this threshold. The more cells that are initially seeded in the test well, the faster the cell accumulation and therefore the shorter the time required to cross this threshold. Therefore, the culture time period required to cross the threshold of each sample corresponds to the original number of cells in the sample. A mutant cell growth time threshold (MT) value of each sample can be calculated to predict the number of original mutant cells. For mutagenesis determination, the RT-CES assay displayed an equal sensitivity ( p > 0.05) and coefficients of variation values with good correlation to conventional HPRT mutagenic assays. Most importantly, the RT-CES mutation assay has a higher throughput than conventional cellular assays. Figure Quantitative analysis of low copy number mutant cells with cell growth kinetic curves. a Low copy number HPRT gene mutant cells are growning on electronic chip and the cell growth kinetic curve is monitored by a real-time cell electronic sensor (RT-CES) system. b When set up a threshold is set at certain level of cell index (CI), the samples with different initial mutant cell copies take different amounts of time in order for their growth (or CI accumulation) to cross this threshold. A mutant cell growth time threshold (MT) value of each sample can be calculated to predict the number of original mutant cells
更多
查看译文
关键词
RT-CES mutagenicity test,Cell growth kinetic curve,High-throughput assay,Low copy number mutant cell,Baseline and threshold analyses
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要