Contamination Of Irrigation Systems Of Dental Units With Cryptosporidium Species In Alexandria, Egypt: A Neglected Disinfection Pitfall

RISK MANAGEMENT AND HEALTHCARE POLICY(2012)

引用 2|浏览2
暂无评分
摘要
Purpose: To investigate the contamination of the dental irrigation systems with Cryptosporidium species in Alexandria, Egypt.Methods: Forty water samples from all 20 working dental irrigation machines in a dental center in Alexandria were included in the study. Water samples were taken from the handpieces of dental irrigation machines in all studied units. After filtration through a membrane filter, water sample residues were stained using modified Ziehl-Neelsen staining and examined microscopically for Cryptosporidium spp.Results: Cryptosporidium spp. was found as a contaminant in 27.5% of water samples taken from dental irrigation machines. Conclusion: This indicates a contamination by the public water supplies to which these dental irrigation machines areconnected. This disinfection pitfall may pose an infection risk to those seeking dental care.
更多
查看译文
关键词
Cryptosporidium, contamination, dental irrigation machines, Alexandria