Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma

BMC Medical Imaging(2012)

引用 1|浏览0
暂无评分
摘要
Background Changes in maximum standardised uptake values (SUV max ) between serial PET/CT studies are used to determine disease progression or regression in oncologic patients. To measure these changes manually can be time consuming in a clinical routine. A semi-automatic method for calculation of SUV max in serial PET/CT studies was developed and compared to a conventional manual method. The semi-automatic method first aligns the serial PET/CT studies based on the CT images. Thereafter, the reader selects an abnormal lesion in one of the PET studies. After this manual step, the program automatically detects the corresponding lesion in the other PET study, segments the two lesions and calculates the SUV max in both studies as well as the difference between the SUV max values. The results of the semi-automatic analysis were compared to that of a manual SUV max analysis using a Philips PET/CT workstation. Three readers did the SUV max readings in both methods. Sixteen patients with lung cancer or lymphoma who had undergone two PET/CT studies were included. There were a total of 26 lesions. Results Linear regression analysis of changes in SUV max show that intercepts and slopes are close to the line of identity for all readers (reader 1: intercept = 1.02, R 2 = 0.96; reader 2: intercept = 0.97, R 2 = 0.98; reader 3: intercept = 0.99, R 2 = 0.98). Manual and semi-automatic method agreed in all cases whether SUV max had increased or decreased between the serial studies. The average time to measure SUV max changes in two serial PET/CT examinations was four to five times longer for the manual method compared to the semi-automatic method for all readers (reader 1: 53.7 vs. 10.5 s; reader 2: 27.3 vs. 6.9 s; reader 3: 47.5 vs. 9.5 s; p < 0.001 for all). Conclusions Good agreement was shown in assessment of SUV max changes between manual and semi-automatic method. The semi-automatic analysis was four to five times faster to perform than the manual analysis. These findings show the feasibility of using semi-automatic methods for calculation of SUV max in clinical routine and encourage further development of programs using this type of methods.
更多
查看译文
关键词
Image analysis,Radionuclide imaging,Quantification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要