Comparison Of Hba1 And Fructosamine In Diagnosis Of Glucose-Tolerance Abnormalities

P. J. Guillausseau,M. A. Charles, F. Paolaggi,J. Timsit,P. Chanson, J. Peynet, V. Godard, E. Eschwege, F. Rousselet, J. Lubetzki

DIABETES CARE(1990)

引用 52|浏览0
暂无评分
摘要
Total glycosylated hemoglobin (HbA1) and fructosamine were evaluated as screening tools for detection of glucose-tolerance abnormalities in 144 asymptomatic subjects undergoing a 75-g oral glucose tolerance test. Subjects were classified according to World Health Organization criteria as having normal (n = 78), impaired (n = 40), or diabetic (n = 26) glucose tolerance. We found good specificity for HbA1 and fructosamine (100 and 97%, respectively) but low sensitivity (15 and 19%, respectively). At the intersection of the curves of sensitivity and specificity drawn from various thresholds of normality, both sensitivity and specificity were 75% for HbA1 and 55% for fructosamine. Thus, neither HbA1 nor fructosamine seems to be suitable for the diagnosis of mild abnormalities in glucose tolerance.