Alignment Effects On A Neutron Imaging System Using Coded Apertures

REVIEW OF SCIENTIFIC INSTRUMENTS(2010)

引用 8|浏览8
暂无评分
摘要
A high resolution neutron imaging system is being developed and tested on the OMEGA laser facility for inertial confinement fusion experiments. This diagnostic uses a coded imaging technique with a penumbral or an annular aperture. The sensitiveness of these techniques to misalignment was pointed out with both experiments and simulations. Results obtained during OMEGA shots are in good agreement with calculations performed with the Monte Carlo code GEANT4. Both techniques are sensitive to the relative position of the source in the field of view. The penumbral imaging technique then demonstrates to be less sensitive to misalignment compared to the ring. These results show the necessity to develop a neutron imaging diagnostic for megajoule class lasers taking into account our alignment capabilities on such facilities.
更多
查看译文
关键词
fusion reactors, laser beam applications, laser fusion, Monte Carlo methods, optical images