Advanced load current multiplier on Zebra generator

Pulsed Power Conference(2011)

引用 3|浏览8
暂无评分
摘要
An improved load current multiplier (LCM) was designed and tested on a high-voltage 100 ns, 0.8-1 MA generator Zebra. The new design allowed to achieve up to ~1.7 MA in plasma loads and up to 1.9 MA in static loads [1]. The previous LCM version provided 1.4 and 1.6 MA accordingly [2]. The load current increase results in the increase of X-ray yield and power from plasma radiation source loads [3]. The advanced LCM represents an integral part of Zebra, inside the generator vacuum section. The new low-inductance design of LCM-to-load connection ensured shielding of the multiplier convolute from load events. Experiments with plasma loads were thus possible without after-shot dismounting of LCM for load installation and diagnostics arrangement. Validation of LCM's on a high-voltage nanosecond generator suggests that the concept could be applicable to existing and future multi-MA fast pulse-power drivers. Anticipating these applications, we present first estimates supporting scaling-up of the LCM technique to multi-terawatt facilities.
更多
查看译文
关键词
electric generators,pulsed power supplies,lcm,lcm-to-ioad connection low-inductance design,x-ray yield,advanced load current multiplier,current 0.8 ma to 1 ma,current 1.4 ma,current 1.6 ma,generator vacuum section,load installation,multiterawatt facilities,plasma radiation source loads,pulse-power drivers,time 100 ns,zebra generator,high voltage,load flow,generators
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper