摘要
The energy density of the inductive energy storage systems is one order of magnitude higher than that of the capacitive ones. Therefore, they have potential applications in the future. In this paper, three inductive pulse power supply (PPS) topologies, i.e., slow transfer of energy through capacitive hybrid meat grinder, XRAM, and nonmutual inductance PPS, are discussed in depth. First, their principles are analyzed. Then, simulations are made to illustrate the principles and prepare the fundamental data for further comparisons based on a 4-kA charging current, 220-μH total inductance system under the environment of Simplorer 8. Five performance indices reflecting their performances from different aspects are proposed in order to ensure objective and comprehensive comparisons. Based on those indices, the advantages and disadvantages of these topologies are pointed out and some potential improvements are also presented.
更多
查看译文
关键词
slow transfer of energy through capacitive hybrid meat grinder,inductive pulse power supplies,simplorer 8 environment,inductive energy storage systems,performance indices,stretch meat ginder,vital indices,energy density,nonmutual inductance pps,capacitive hybrid meat grinder,pulsed power supplies,inductive energy storage,xram,comparisons,current 4 ka,pps topology,three inductive pulse power supplies,topology,switches,capacitors,inductors,thyristors,inductance