The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: 1. (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within ± 20° C of the measured values for ΔNDT. None of the different methods is clearly superior; 2. (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and 3. (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment.