A comparative analysis of periapical radiography and cone-beam computerized tomography for the evaluation of endodontic obturation length.
Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology(2011)
摘要
The aim of this study was to determine the consistency and inconsistency between the periapical radiography (PR) and cone-beam computerized tomography (CBCT) in evaluating the length of root canal obturations (RCOs) in vivo.Thirty-six maxillary and mandibular first and second molars yielding 109 obturated root canals with available PR and CBCT images were analyzed. The inclusion criterion was that the RCO extended 0-2 mm short of the radiographic apex on PR images. Teeth having root canal calcification, apical resorption, or poor quality PR/CBCT images were excluded. Agreement and disagreement between the 2 imaging modalities for obturation length were analyzed using the χ(2) test.A total of 30.3% of the RCOs evaluated by PR as having adequate length were diagnosed by CBCT to have inadequate length. Among these, 13.8% were overextended and 16.5% underextended as diagnosed by CBCT. When the distance from the filling tip to the radiographic apex was 0.5 to 1 mm on the PR image, the discordance rate was the lowest (11.1%) in all evaluated distance groups, significantly lower than with distances of 0-0.5 mm and 1.5-2 mm (P < .01). When RCOs were diagnosed as terminating at the facial/lingual side, overextension was the main evaluation result by CBCT in the disagreement evaluation with PR and significantly more frequent than those at the mesial/distal/central side (P < .01).CBCT evaluated 30.3% of the RCOs with radiographically adequate length as inadequate. When the RCOs radiographically terminated 0.5-1 mm short of the apex, the evaluation rated adequate for obturation length was comparatively reliable.
更多查看译文
关键词
comparative analysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要