Disappearance of Spontaneous Echographic Contrast after Balloon Mitral Valvuloplasty: An Indicator of Sustained Hemodynamic Improvement

Journal of Interventional Cardiology(1990)

引用 1|浏览6
暂无评分
摘要
In three patients undergoing mitral balloon valvuloplasty for mitral stenosis transesophageal echocardiography was performed before, immediately after, and 6 months after the procedure. In the one patient with persistent hemodynamically favorable result, the spontaneous echocardiographic contrast, which was seen in all three preoperatively, did not recur; in the other two patients the phenomenon was observed again after 6 months. We conclude that the disappearance of spontaneous echocardiographic contrast might be a functional morphological measure of sustained hemodynamic improvement after balloon mitral valvuloplasty. Copyright
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要