Mini-Laparoscopy In The Endoscopy Unit: Safety And Outcomes In Over One Thousand Patients

World journal of gastrointestinal endoscopy(2011)

引用 16|浏览2
暂无评分
摘要
AIM: To investigate the safety of consecutive mini-laparoscopy guided liver biopsies for the diagnosis and staging of liver diseases.METHODS: In this study we retrospectively analyzed the safety of mini-laparoscopic liver biopsy performed in an endoscopy unit in 1071 patients. We measured the incidence of bleeding and evaluated the management and outcome of bleeding interventions.RESULTS: The most common etiologies of liver injury were viral hepatitis and autoimmune liver disease. 250 patients had macroscopically and histologically proven cirrhosis. 13 patients had no pathological findings. 33% of all patients had bleeding that required argon plasma coagulation of the puncture site during laparoscopy. Significant bleeding occurred more often in patients with liver cirrhosis compared to non-cirrhotic liver diseases but was effectively treated with laparoscopic coagulation.CONCLUSION: In conclusion, mini-laparoscopy liver biopsy can be performed safely and effectively in high risk patients with advanced liver disease; mini-laparoscopy with liver biopsy can be done safely in an endo-scopy unit. (C) 2011 Baishideng. All rights reserved.
更多
查看译文
关键词
Mini-laparoscopy,Cirrhosis,Argon plasma coagulation