Observations Of Rising Tune During The Injection Instability Of The Ipns Rcs Proton Bunch

J. C. Dooling, F. R. Brumwell, L. I. Donley,K. C. Harkay, R. L. Kustom, M. K. Lien, G. E. Mcmichael, M. E. Middendorf,A. Nassiri, S. Wang

2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11(2007)

引用 0|浏览12
暂无评分
摘要
In the Rapid Cycling Synchrotron (RCS), a single proton bunch (h=1) is accelerated from 50 MeV to 450 MeV in approximately 14.2 ms. The bunch experiences an instability shortly after injection (<1 ms). During the first millisecond, the beam is bunched but little acceleration takes place; therefore this period is similar to a storage ring mode of operation. Natural vertical oscillations (assumed to be tune lines) show the vertical tune to be rising toward the bare time value, suggesting neutralization of space charge and a reduction of its detuning effects. Neutralization time near injection ranges from 250 mu s - 500 mu s, depending on the background gas pressure. Oscillations move from the LSB to the USB before disappearing. Tune measurements made with a recently installed ferrite-magnet pinger system show the horizontal chromaticity to be positive early but approaching zero later in the cycle; on the other hand, the vertical chromaticity is negative throughout the cycle. During pinger studies near injection, two vertical lines are observed. Neutralization of the beam space charge implies the generation of plasma in the beam volume early in the cycle which may then dissipate as the time-varying electric fields of the beam become stronger.
更多
查看译文
关键词
electric field,oscillations,protons,acceleration,space charge,electric fields,time measurement,magnets