Magic angle effect in MR imaging of ankle tendons: influence of foot positioning on prevalence and site in asymptomatic subjects and cadaveric tendons

European Radiology(2006)

引用 48|浏览4
暂无评分
摘要
The influence of foot positioning on prevalence of the magic angle effect (MAE) in ankle tendons was investigated. In 30 asymptomatic volunteers and five cadaveric feet, MR imaging of the ankle was performed in the supine (neutral position of the foot) and prone (plantar-flexed foot) position. MAE was considered if increased T1-weighted signal at a certain site was seen in one position only. Histological correlation was obtained at 25 sites of the cadaveric posterior tibialis tendons (PTT). MAE occurred in 6/30 vs 1/30 (supine vs prone) anterior tibialis tendons (ATT), 30/30 vs 0/30 extensor hallucis longus and 27/30 vs 0/30 extensor digitorum longus tendons, 29/30 vs 0/30 PTTs, 30/30 vs 0/30 flexor digitorum and flexor hallucis longus tendons, 30/30 vs 1/30 peroneus brevis and 23/30 vs 1/30 peroneus longus tendons. At 12/25 cadaveric PTT sites where MAE was exclusively responsible for the increased signal, histology revealed normal tissue (11/12) or minimal degeneration (1/12). In conclusion, the supine body position with neutral position of the foot, a high prevalence (77–100%) of MAE in ankle tendons except for the ATT (20%) is seen. MAE is almost absent in the prone body position with plantar flexion of the foot.
更多
查看译文
关键词
MR imaging,tendon,ankle
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要