On/Off Control of Boost PFC Converters to Improve Light-Load Efficiency in Paralleled Power Supply Units for Servers

IEEE Transactions on Industrial Electronics(2014)

引用 44|浏览9
暂无评分
摘要
This paper proposes an on/off control of boost power factor correction (PFC) converters to improve the light-load efficiency in paralleled power supply units (PSUs) for servers. The proposed scheme operates the PFC stages of two paralleled PSUs alternately during one cycle of a 60-Hz ac input only at light loads. This improves the light-load efficiency without deteriorating the heavy-load efficiency by reducing load-independent losses such as capacitive turn-on and core losses. In addition, the proposed scheme alleviates the harmonic distortion by reducing the discontinuous conduction mode region. Experimental results from 1.6-kW PFC boost converters are shown to verify the proposed work.
更多
查看译文
关键词
paralleled psu,load regulation,power convertors,harmonic distortion,frequency 60 hz,power supply units,power supply circuits,discontinuous conduction mode region,load-independent losses,servers,on/off control,boost pfc converters,power 1.6 kw,power factor correction,paralleled power supply units (psus),power factor correction (pfc),boost converter,losses,light-load efficiency,on-off control