[Treatment of type c fractures of the distal radius with volar locking compression plate and radial styloid process plate].

Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery(2012)

引用 24|浏览26
暂无评分
摘要
OBJECTIVE:To analyze the effectiveness ofvolar locking compression plate (LCP) and radial styloid process plate for the treatment of type C fractures of the distal radius. METHODS:Between May 2010 and May 2011, 24 cases of type C fractures of the distal radius were treated, including 8 males and 16 females with an average age of 52 years (range, 23-73 years). Injury was caused by falling in 20 cases and by traffic accident in 4 cases. All were fresh closed fractures. The locations were the left side in 15 cases and the right side in 9 cases. According to AO typing, there were 16 cases of type C2 and 8 cases of type C3. The preoperative palmar tilt angle ranged from 60 to 25 degrees (mean, -45.3 degrees); the preoperative ulnar inclination angle ranged from 16 to 13 degrees (mean, 8.2 degrees); and the preoperative radial length shortening was 8-18 mm (mean, 12 mm). The time from injury to operation was 3-10 days (mean, 5.2 days). RESULTS:All operation incisions healed primarily. All patients were followed up 9-16 months (mean, 13.5 months). The healing time of fracture was 8-12 weeks (mean, 10.2 weeks). The articular surface was smooth and the radial length was recovered. The postoperative palmar tilt angle ranged from 8 to 15 degrees (mean, 12.3 degrees); the postoperative ulnar inclination angle ranged from 18 to 26 degrees (mean, 22.3 degrees). No loss of reduction, refracture, or carpal tunnel syndrome occurred during follow-up. The average range of motion of the wrist was 45.3 degrees (range, 30-70 degrees) in dorsal extension, was 50.2 degrees (range, 26-78 degrees) in palmar flexion, was 13.5 degrees (range, 8-25 degrees) in radial inclination, was 23.6 degrees (range, 15-32 degrees) in ulnar inclination, was 65.7 degrees (range, 35-90 degrees) in pronation, and was 72.5 degrees (range, 20-90 degrees) in supination at last follow-up. According to the wrist function by Gartland-Werley scoring, the results were excellent in 12 cases, good in 8 cases, and fair in 4 cases; and the excellent and good rate was 83.3%. CONCLUSION:Treatment of type C fractures of the distal radius with volar LCP and radial styloid process plate can reconstruct normal anatomic structures and get good functional recovery.
更多
查看译文
关键词
fracture of distal radius locking compression plate internal xation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要