Enantioselective determination of FCE 28833, a new potential antiischemic agent, in gerbil plasma using column switching HPLC with UV detection.

CHIRALITY(1997)

引用 3|浏览6
暂无评分
摘要
A sensitive and selective high performance liquid chromatographic method using an automated column switching technique for the determination of FCE 28833 enantiomers in gerbil plasma was developed. After solid-liquid extraction using a Supelcosil C-18 cartridge, FCE 28833 was eluted on a clean-up column (Spherisorb CN) and the enantiomers were separated using an analytical chiral column (Crownpack CR(+)). The mobile phase (15% methanol in HClO4 1 mM) was directed through the columns at a flow rate of 1 ml/min and the fraction eluted between 13 and 40 min was transferred from the clean-up column into the analytical column. FCE 28833 enantiomers were monitored at 257 nm. The limit of quantitation of the method was 20 ng/ml plasma for both enantiomers and proved to be linear, precise, and accurate for the assay of both enantiomers in the 20-6,000 ng/ml concentration range. No interference from the blank gerbil plasma sample was observed. The suitability of the method was assessed using plasma samples obtained from male gerbils treated with a single oral dose (400 mg/kg) of FCE 28833. (C) 1997 Wiley-Liss, Inc.
更多
查看译文
关键词
anti-ischemic agent,gerbil,enantiomeric resolution,column switching,chiral crown ether HPLC