Ion chromatographic separation for analysis of radiostrontium in nuclear reprocessing solutions of high ionic strength

Journal of Radioanalytical and Nuclear Chemistry(2005)

引用 16|浏览5
暂无评分
摘要
Determination of90Sr in nuclear fuel reprocessing solutions can be facilitated by a preparatory separation using analytical ion chromatography (IC). Furthermore, a novel acid suppression system is described which permits IC separation even in the presence of very strong (0.33M) acid. Following acid suppression (where needed), Sr2+ is concentrated and separated from most other solution components by selective adsorption on cation concentrator columns. Cation species retained on the concentrator columns with strontium are subsequently separated on a cation IC column. The Sr2+ peak aliquot is collected for subsequent radiostrontium analysis by liquid scintillation counting of the beta activity. Results have shown quantitative separation and recovery of strontium. The entire separation system is automated under computer control and is able to handle samples of large (500 ml) and small (l) sizes.
更多
查看译文
关键词
Strontium,Nuclear Fuel,Liquid Scintillation Counting,High Ionic Strength,Acid Suppression