Plasma-induced damage study for n-GaN using inductively coupled plasma reactive ion etching

JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B(2001)

引用 42|浏览9
暂无评分
摘要
In this article, we report a comprehensive study on plasma-induced damage for n-GaN using inductively coupled plasma (ICP) reactive ion etching. Effect of ICP coil power, etch duration and bias voltage on the electrical characteristics of n-GaN was investigated. It was observed that variation in ICP coil power and etch duration had minimal effect on varying the plasma-induced surface damage. Bias voltage was found to be the most significant cause of variation in plasma-induced damage to the surface of n-GaN. Therefore, low surface damage can be achieved by optimizing the bias voltage at which the sample is being etched. Auger electron spectroscopy analysis showed that the stoichiometry of the etched GaN surfaces was identical, independent of the etching conditions. (C) 2001 American Vacuum Society.
更多
查看译文
关键词
reactive ion etching,inductive coupled plasma
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要