Variable toxicity of dyes used in micropuncture studies

David J Nikolic-Paterson,Lynette A Hurst,Wayne D Comper

NEPHROLOGY(2001)

引用 2|浏览8
暂无评分
摘要
This study evaluated the potential toxicity of Fast green and Lissamine green, the two dyes commonly used for visualizing tubular fluid flow in micropuncture studies. In both the in vitro perfused kidney and cultured tubular epithelial cells, Fast green exhibited a profound, dose-dependent toxicity. In contrast, Lissamine green was non-toxic. In conclusion, we recommend that Fast green not be used in micropuncture studies.
更多
查看译文
关键词
Fast green,Lisamine green,micropuncture,toxicity,tubules