Aortic Surgery Complications Evaluated by an Implanted Continuous Electrocardiography Device: A Case Report

European Journal of Vascular and Endovascular Surgery(2011)

引用 2|浏览14
暂无评分
摘要
Cardiac arrhythmias are a major cause for morbidity and mortality in patients undergoing non-cardiac vascular surgery.An implantable loop recorder (Reveal(®) XT) was used for continuous heart rhythm monitoring to detect perioperative arrhythmias in a 69-year-old man undergoing major vascular surgery for an infected aortobifemoral prosthesis. The Reveal(®) detected several episodes of asymptomatic new-onset atrial fibrillation postoperatively, associated with elevated serum levels of troponin-T and N-terminal pro-B-type natriuretic peptide NT-proBNP).Continuous heart rhythm monitoring with assessment of serum cardiac biomarkers may allow early identification and treatment of patients at high risk of perioperative cardiovascular complications, in particular, cardiac arrhythmias.
更多
查看译文
关键词
Heart rhythm monitoring,Biomarkers,Vascular surgery