Stable Operation With Gain Of A Double Phase Liquid Argon Lem-Tpc With A 1 Mm Thick Segmented Lem

1ST INTERNATIONAL WORKSHOP TOWARDS THE GIANT LIQUID ARGON CHARGE IMAGING EXPERIMENT(2011)

引用 11|浏览16
暂无评分
摘要
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for next-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3 lt chamber equipped with a 10x10 cm(2) readout, cosmic muon data was recorded during three weeks of data taking. A maximum gain of 6.5 was achieved and the liquid argon was kept pure enough to ensure 20 cm drift (O(ppb) O-2 equivalent).