Development of the polarimetry with NMR for polarized HD target

msra

引用 23|浏览9
暂无评分
摘要
In the polarized Hydrogen-Deuteride (HD) target project (1), we plan to measure the double polarization asymmetries for themeson photoproduction. High polarization will be obtained by applying high magnetic field (17T) at low temperature (10mK). In the case of proton in HD, the polarization is expected to be 95%. Accurate measurements of the target polarization are essential in this project. With this aim in mind, we are developing the polarimetry with "steady" NMR. When the magnetic field (or NMR frequency) is swept, an area of spectrum obtained from steady NMR signal is proportional to the target polarization. As a first step, we have obtained NMR spectra of the liquid H2 to check our NMR system with the single coil method, in which a single coil is used for both transmitter and receiver coils. When the single coil is used, one should construct an electronic circuit so that an rf signal from a transmitter does not mix with a signal from a receiver. Therefore, we used a cancellation circuit which is proposed by Jeerey and Armstrong (2) as shown in Fig.1(a). We used a cylindrical sample cell made of Stycast1266 with an inner-diameter of 11mm and a length of 28mm as shown in Fig.1(a). The NMR coil has a saddle shape and covers the whole region of the cell. The H2 sample was liquefied at 17K by "Storage Cryostat (SC)" which is a 4He cryostat with a superconducting magnet. The magnetic field was swept from 0:405 to 0:41Tesla and the NMR frequency was fixed at 17:8MHz. Figure1(b) shows the NMR spectra of the sample cell in which liquid H2 is filled. The NMR spectrum consists of two parts; a sharp peak at 0:407Tesla and a broad one around the sharp peak. We observed a broad peak even with an empty sample, which suggests that the broad peak is due to the proton in Stycast and the sharp peak comes from liquid H2. The longitudinal relaxation time T1 of NMR is related to the intensity of the signal and the transverse relaxation time T2 is related to the line width. The line width of the sharp peak is consistent with the value estimated from the inhomogeneity of the magnet field in the sample cell, reflecting a long T2 of the liquid H2. On the other hand, the broad one reflects a short T2 of Stycast. The signal of Stycast is quite large, which means that a proton system in Stycast has a short T1. Thus, we will use a sample cell made of proton-free material, for example Kel-F to extract a clearer signal of the sample. In the future, we will measure the polarization of solid HD target with this polarimetry.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要