Multi-state control strategy of starting for a wet friction clutch via a fuzzy logic algorithm

International Journal of Automotive Technology(2011)

引用 9|浏览4
暂无评分
摘要
Wet multi-plate friction clutches are used in automotive drivelines to transfer torque, change gears, and prevent motion by locking-up components in the transmission. The control strategy of starting is a crucial technology for the application of a wet multi-plate friction clutch in the automotive industry. In this paper, a multi-state fuzzy control strategy for starting is presented and applied to a continuously variably transmission (CVT) powertrain for the validation of this strategy. The operation of the clutch was divided into four states: parking, starting, riding and emergency. The starting state was investigated in detail. A fuzzy algorithm was employed to control the pressure of the hydraulic cylinder acting on the clutch. A distinguishing feature is that the pressure does not increase but decreases to implement smooth starting during the initial period of starting. The rapid-control prototype (RCP) of the wet friction clutch was developed to validate the new control strategy onboard a test vehicle. Based on the experimental results, the multi-state control strategy for a wet friction clutch is a viable candidate for engineering applications.
更多
查看译文
关键词
Wet friction clutch,Starting,CVT,RCP,Fuzzy control