Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography

Intensive Care Medicine(2009)

引用 37|浏览6
暂无评分
摘要
Objective To determine the global and regional changes in lung volume during and after closed endotracheal tube (ETT) suction in high-frequency ventilated preterm infants with respiratory distress syndrome (RDS). Design Prospective observational clinical study. Setting Neonatal intensive care unit. Patients Eleven non-muscle relaxed preterm infants with RDS ventilated with open lung high-frequency ventilation (HFV). Interventions Closed ETT suction. Measurements and results Changes in global and regional lung volume were measured with electrical impedance tomography. ETT suction resulted in an acute loss of lung volume followed by spontaneous recovery with a median residual loss of 3.3% of the maximum volume loss. The median stabilization time was 8 s. At the regional level, the lung volume changes during and after ETT suction were heterogeneous in nature. Conclusions Closed ETT suction causes an acute, transient and heterogeneous loss of lung volume in premature infants with RDS treated with open lung HFV.
更多
查看译文
关键词
Endotracheal suction,Premature infant,High-frequency ventilation,Electrical impedance tomography